Dell PowerEdge M620 Owner's Manual page 125

Hardware owner's manual
Hide thumbs Also See for PowerEdge M620:
Table of Contents

Advertisement

Table 1-27. Blade Messages
Message
Error: Incorrect
memory
configuration.
DIMMs must be
installed in pairs
of matched memory
size, speed, and
technology.
Error: Incorrect
memory
configuration.
System halted.
Error: Memory
failure detected.
Memory size
reduced. Replace
the faulty DIMM as
soon as possible.
Error programming
flexAddress (MAC)
for bus, device,
function.
Error programming
flexAddress (iSCSI
MAC) for bus,
device, function.
Error resetting
NIC after
programming
flexAddress for
bus, device,
function.
(continued)
Causes
Mismatched or
unmatched DIMMs
installed; faulty or
improperly seated memory
modules.
Less than 512 MB of
memory installed.
Faulty or improperly
seated memory modules.
FlexAddress (virtual
MAC) is not supported on
the specified device.
FlexAddress (virtual
MAC) is not supported on
the specified device.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Corrective Actions
Ensure that all pairs of
memory modules are of the
same type and size, and that
they are properly installed.
See "System Memory" on
page 171 If the problem
persists, see
"Troubleshooting Blade
Memory" on page 319.
Add memory modules to
achieve a configuration
supported by the system.
See "System Memory" on
page 171.
See "Troubleshooting Blade
Memory" on page 319.
Information only.
Information only.
Information only.
About Your System
125

Advertisement

Table of Contents
loading

Table of Contents