Dell PowerEdge M620 Owner's Manual page 110

Hardware owner's manual
Hide thumbs Also See for PowerEdge M620:
Table of Contents

Advertisement

Table 1-26. LCD Status Messages
Code
Text
E2012 Memory
configured
but unusable.
Check DIMMs.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
E2014 CMOS RAM
failure.
Power cycle
AC.
E2015 DMA
Controller
failure.
Power cycle
AC.
E2016 Interrupt
Controller
failure.
Power cycle
AC.
E2017 Timer refresh
failure.
Power cycle
AC.
110
About Your System
(continued)
Cause
Memory configured, but is
unusable.
The system BIOS failed to
copy its flash image into
memory.
CMOS failure. CMOS
RAM not functioning
properly.
DMA controller failure.
Interrupt controller failure. Remove AC power to the
Timer refresh failure.
Corrective Actions
See "Troubleshooting
Blade Memory" on
page 319.
See "Troubleshooting
Blade Memory" on
page 319.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.

Advertisement

Table of Contents
loading

Table of Contents