Table 1-26. LCD Status Messages
Code
Text
E1618 Predictive
failure on
Power Supply
# (### W).
Check PSU.
E161C Power Supply
# (### W)
lost AC
power. Check
PSU cables.
E1620 Power Supply
# (### W) AC
power error.
Check PSU
cables.
E1624 Lost power
supply
redundancy.
Check PSU
cables.
E1626 Power Supply
Mismatch.
PSU1 = ### W,
PSU2 = ### W.
108
About Your System
(continued)
Cause
Specified power supply has
detected a condition that
may predict a future power-
down event, such as an
over-temperature warning
or PSU communication
error, that could develop
into a fault condition in the
power supply.
Specified power supply is
attached to the system, but
it has lost its AC input.
Specified power supply's
AC input is outside of the
allowable range.
The power supply
subsystem is no longer
redundant. If the remaining
power supply fails, the
system shuts down.
The power supplies in the
system are not the same
wattage.
Corrective Actions
See "Troubleshooting
Power Supply Modules"
on page 314.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supply Modules" on
page 314.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supply Modules" on
page 314.
See "Troubleshooting
Power Supply Modules"
on page 314.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system's Getting
Started Guide.

Advertisement

Table of Contents
loading