Center Knife - Duerkopp Adler 745-26 Service Instructions Manual

Hide thumbs Also See for 745-26:
Table of Contents

Advertisement

15.13 Center Knife

94
Caution Risk of Injury !
Turn the main switch off.
Set the center knife only with the main switch turned off.
Position of the center knife at lower dead center
The forward edge 4 of the moving knife 3 must lie 1 mm above the
cutting edge of the fixed knife at the lower dead center.
1
2
3
4
Loosen screws 2.
Set the height of the center knife 3.
Tighten screws 2.
Loosen screw 1.
Loosen screws 6.
Set the knife holder 5 with the center knife 3 to the left against the
fixed knife in the needle plate.
The center knife 3 must lay on parallel and with a light pressure.
Tighten screw 1 and screws 6.
Conduct a cutting trial.
To correct: Set the center knife 3 to cut by turning the knife
holder 5 slightly to the left.
5