15. Machine Head

15.1 Crank Pin on the Arm Shaft

1
2
70
The clearance of the eccentric crank pin 1 to the arm shaft 4
determines the size of the needle bar stroke and thus the upper dead
center of the commonly and separately switchable needle bars.
ATTENTION !
The crank pin 1 is precisely set at the factory!
After a replacing of the thread lever or when the needles no longer
switch off correctly, then the crank pin 1 is to be reset.
3
4
The setting of the crank pin 1 occurs with the gauge 13 (Order no.
0246 002591). The crank and the arm shaft need not be removed for
the setting.
Caution Risk of Injury !
Turn the main switch off.
Set the crank pin only with the main switch turned off.
Turn the main switch off.
Loosen screws 7 and 9.
Remove cylinder 11 with swing lever 12.
Remove the head cover 10 after loosening the mounting screws.
Remove the needle bar link (see Chapter 15.2.4).
Loosen the needle tie rod from crank pin 1 after screwing out its
mounting screw (Attention: Left-hand thread!) and pull off with the
needle cage.
Turn the handwheel until the Allan screws 2 show downward.
The Allan screws 2 are accessible in this position.
Loosen Allan screws 2.
5
6

Hide quick links: