EPSON EPL-N1600

4.3.31 Fuser Assembly

1. Remove the Cover Side,E. (Section 4.2.1)
2. Remove the Control Assembly Panel (E). (Section 4.2.3)
3. Remove the Cover Assembly MBF.E.(Section 4.2.4)
4. Remove the Tray Assembly MBF.E.(Section 4.2.5)
5. Remove the Cover Assembly,E. (Section 4.3)
6. Remove the Roll Assembly Exit Out. (Section 4.3.27)
7. Disconnect J291 from the Fuser Assembly.
8. Disconnect P/J11 on the wires (AC supply circuit) from the PWBA
PS.
9. Remove the four screws that secure the Fuser Assembly to the
Printer Frame.
10. Lift up the left side (drive side) of the Fuser Assembly, then lift the
entire Fuser Assembly out of the Frame.
Be careful not to break the Actuator Exit-2/L or 2/S
when replacing the Fuser Assembly. If you attempt to
lower the Fuser Assembly with the Fuser Assembly
being caught by the Actuator Exit-2/L or -2/S, the
Actuator can break. Raise the Actuators Exit-2/L and 2/
S when lowering the Fuser Assembly into place so that
the Fuser Assembly is not caught by the Actuator Exit-
2/L or -2/S.
Rev. A
Chapter 4
Disassembly and Assembly
Figure 4-37. "Fuser Assembly" Removal
4-140