EPSON EPL-N1600
Signal Name
/TR+
Control signal which switches on and off the Transfer Bias
voltage applied to the BTR. The Transfer Bias voltage is not
applied when this signal is High and applied when Low.
/TR-
Signal which switches the polarity of the Transfer Bias voltage.
The Transfer Bias voltage is positive when this signal is Low
and negative when High.
/DTS
Control signal which switches on and off the voltage to the
Detack Saw. The voltage is not applied when this signal is Low
and applied when High.
TR A/D
Monitoring signal which indicates the Transfer Bias current to
the BTR (Analog signal)
TR D/A
Control signal which determines the value of the Transfer Bias
current.
Rev. A
Description
Table 7-3. Pin Assignment / HPS - Controller
Signal Direction
M: Controller
P21
Signal Name
P: HPS
A5
/HEAT
M
P
A6
NO TONER
M
P
A7
/PRE REG
M
P
A8
/CR-DC
M
P
A9
/CR-AC
M
P
A10
/DB-AC
M
P
A11
/DB-DC
M
P
B2
Fan Alarm
M
P
B4
5V-LD
M
P
B5
NO PAPER 1
M
P
B6
/REG IN
M
P
B7
TR
M
P
B8
TR+/-
M
P
B9
/DTS
M
P
B10
TR A/D
M
P
B11
TR D/A
M
P
Chapter 7
Appendix
High
Low
Trigger
Level
Level
Level
4~5 VDC
0~0.8 VDC
Level
TTL
TTL
Level
TTL
TTL
Level
24 VDC
0~0.8 VDC
Level
24 VDC
0~0.8 VDC
Level
24 VDC
0~0.8 VDC
Level
4~5 VDC
0~0.8 VDC
Level
TTL
TTL
-
4~5 VDC
0~0.8 VDC
Level
TTL
TTL
Level
TTL
TTL
Level
24 VDC
0~0.8 VDC
Level
24 VDC
0~0.8 VDC
Level
24 VDC
0~0.8 VDC
-
*
*
-
*
*
172