Preset Weight Comparators Setup (Mode Of Operation = 3) - Cardinal 225 Installation And Technical Manual

Weight indicator
Table of Contents

Advertisement

PRESET WEIGHT COMPARATORS SETUP
Mode of Operation
ETUP MENU #1 displayed the current setting for the MODE OF OP= parame
With S
be sho
wn. Press the 1 and 0 keys and then the ENTER key. The display will change to s
the Mo
de Of Operation Menu. Press the 3 key and then the ENTE
Weight Comp. The display will change to show the ID Storage Menu.
Preset
1. OUTPUTS=XX
2. BAL PRNT=XXX
Enter Selection: 0
1.
OUTPUTS (NUMBER OF PRESET WEIGHT COMPARAT
W
ith the Preset Weight Comparator Menu displayed the current setting for the
OUTPUTS= parameter will be show
displayed is acceptable, proceed to the next setup parameter.
Otherwise, press the 1 key, the ENTER key and then using the numeric keys, ente
v
alue for the number of PWC outputs and then press the ENTER key to save the new
setting and return to the ID Storage Menu. Allowable values are: 1 through 16.
1
Low State before cutoff with 1 active Preset
2
Low State before cutoff with 2 active Presets
3
Low State before cutoff with 3 active Presets
4
Low State before c
5
Low State before cutoff with 5 active Presets
6
Low State before cutoff with 6 active Presets
7
Low State before cuto
8
Low State before cutoff with 8 active Presets
9
High State before cutoff with 1 active Preset
10
High State before cutoff with 2 active Presets
11
High State before cutoff with 3 active Presets
12
High State before cutoff with 4 active Presets
13
High State before cutoff with 5 active Presets
14
High State before cutoff with 6 active Presets
15
High State before cutoff with 7 active Presets
16
High State before cutoff with 8 active Presets
*
The relay state is based on using Cardinal Scale relays (p/n 6850-1013). If using relays
other than those supplied by Cardinal Scale, refer to the relay manufacturers specifications.
NOTE! When power to the 225 is lost, the output returns to a Low State condition.
8200-M538-O1 225 Installation
Preset Weight Comparator Menu
utoff with 4 active Presets
ff with 7 active Presets
= 3 (Preset Weight Comp)
^
EXIT
n. Note that XX is the current value. If the setting
ter will
R key to select
ORS "PWC")
Relay*
Open
Relay*
Closed
Page 78
how
r the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents