The Model 225 indicator will respond to ASCII coded serial data, in the format below, when
input to the RXD serial input or the IR port.
The commands are ASCII strings, without spaces, fo
and can be upper or lower case, or any combination.
Data inside parenthesis is the
the value of PWC number 1 preset to be transmitted from the indicator).
A command fol
the data desired to be stored for that parameter.
Any command w
(a query command).
Commands that set more than one value use commas b
To verify data has been stored correctly in
the s
ame data to be transmitted from the indicator.
Commands
Command
U
U
Gross<cr>
Tare<cr>
Tare=123<cr>
Net
<cr>
PWC (1)<cr>
PWC (1)=123<cr>
Fas
t<cr>
Fast=123<cr>
Slow<cr>
Slow=123<cr>
Fill<cr>
Fill=123<cr>
Trim<cr>
Trim=123<cr>
Accum(g)<cr>
Accum(n)=100<cr>
Ing(1)<cr>
Ing(1)=1,100,150<cr>
Trim(1)<cr>
Trim(1)=100<cr>
ID()<cr>
ID(1)<cr>
ID(1)=ref,100,0<cr>
Key(x)<cr>
<cr> = carriage return
8200-M538-O1 225 Installation

ASCII COMMANDS

parameter item designator (e.g. "PWC (1) <cr>" requests
lowed by the equal sign "=" is a set command and must be followed by
ithout an equal sign requests data to be transmitted from the indicator
Response
U
U
1000lb G
1
00lb T
OK
9
00lb N
10
0lb PWC1
O
K
100lb F
OK
100lb F
OK
100lb F
OK
100lb TRM
OK
1000lb
OK
1 100lb 1200lb
OK
100lb TRM1
OK
id(x)=r,1,2
id(1)=r,1,2
OK
Results of (x) function.
llowed by a carriage return <cr>
etween the values.
the indicator, send the command to request
Description
U
U
Transmit Gross Weight
Transmit Current Tare
Set Tare To Value
Transmit Net Weight
T
ransmit PWC Value
Set PWC To Val
ue
Transm
it 2 Speed DFC Fast Value
Set 2 Speed DFC Fast Value
Transmit 2 Speed DFC Slow Value
Set 2 Speed DFC Slow Value
Transmit 1 Speed DFC Value
Set 1 Speed DFC Value
Transmit DFC Trim Value
Set DFC Trim Value
Transmit Accumulator Valid Selections
G/N/C/1-7
Set Accumulator
Transmit Ingredient (Bin,Fast,Slow)
Set Ing (Bin,Fast,Slow)
Transmit Batcher Trim For Ing X
Set Batcher Trim
List ALL IDs ID(ID)=Ref,Tare,Accum
List A Single ID
Add Or Replace An ID
Performs function of (x) as if key was
pressed. See Valid Key Names.