Information About Topology-Related Parameters; Sce 2000 Configuration; Connection Mode Parameter - Cisco SFE2000P Installation And Configuration Manual

Configuration guide
Hide thumbs Also See for SFE2000P:
Table of Contents

Advertisement

Information About Topology Considerations

Information About Topology-Related Parameters

Refer to the following sections to determine the correct values for all topology-related parameters before
beginning run the initial setup of the SCE 2000 .

SCE 2000 Configuration

There are four topology-related parameters:
Any of these parameters may be configured via either the setupcommand or the
connection-modecommand.

Connection Mode Parameter

The connection mode parameter refers directly to the physical topology in which the SCE 2000 is
installed. The connection mode depends on two factors:
The connection mode parameter is determined by the physical deployment of the SCE 2000 , as follows:
Cisco SCE 2000 4xGBE Installation and Configuration Guide
3-10
SCE 2000 Configuration
Connection Mode Parameter
Physically Connected Links Parameter
Priority
On-Failure Mode Parameter
Connection mode — Can be any one of the following, depending on the physical installation of the
SCE 2000 (Refer to
Connection Mode Parameter
Inline — single SCE 2000 inline
Receive-only — single SCE 2000 receive-only
Inline-cascade — two SCE 2000 s inline
Receive-only-cascade — two SCE 2000 s receive-only
Physically-connected-links — In cascaded configurations, this parameter defines the number of the
link connected to this SCE 2000 (Refer to
It is applicable only in a cascade topology.
Priority — This parameter defines which is the primary SCE 2000 (Refer to
It is applicable only in a cascade topology.
On-failure — This parameter determines whether the system cuts the traffic or bypasses it when the
SCE 2000 either has failed or is booting. It is not applicable to receive-only topologies (Refer to
On-Failure Mode Parameter
Inline/Receive-only :
Inline — The SCE 2000 resides on the data link between the subscriber side and the network
side, thus both receiving and transmitting packets.
Receive-only — The SCE 2000 does not reside physically on the data link. Data is forwarded
to the SCE 2000 via an external switch. The SCE 2000 itself receives only and does not
transmit.
Cascade — Indicates a two SCE 2000 topology where the SCE 2000 are connected via the cascade
ports.
):
Physically Connected Links Parameter
).
Chapter 3
Information About Topology
).
Priority
).
OL-7824-06