Chapter 8
Troubleshooting
Table 8-2
SCE 2000 Operational Status
Warning
Failure
OL-7824-06
SCE 2000 Operational States
Description
SCE 2000 is fully operational
(as above) but one of the
following occurred:
Line ports (GBE ports) to
the link are down
Management port link is
down
Temperature raised above
threshold
Voltage not in required
range
Fans problem
Power supply problem
Insufficient space on the
disk
Note
System is in Failure state after
Boot due to one of the following
conditions:
Power on test failure
Three abnormal reboots in
less than 20 minutes
Platform configured to enter
Failure mode consequent to
failure-induced reboot (this
is configurable using CLI
command)
Note
Warning Note: If the
condition that caused the
SCE 2000 to be in
Warning state is resolved
(for example, link is up)
the SCE 2000 reverts to
Operational state.
Flashing orange
Depending on the cause
of failure, the
management interface
and the platform
configuration may or
may not be
active/available. Red
Cisco SCE 2000 4xGBE Installation and Configuration Guide
Troubleshooting Overview
Status LED State
Warning Flashing orange
Red
8-5