ENGINE TEST MODE

Detailed Description (Engine Test Mode)

Function name
01. Motor test
02. Pick-up test
03. Fan test
04. Manual clutch test
05. PTL (Pre-Transfer
Lamp) test
11. LSU motor
12. LSU Hsync test
13. LD test
21. Feed sen test
22. Exit sen test
23. Cover sen test
24. Empty sen test
25. Manual sen test
31. Therm ADC 180
32. Therm ADC 140
33. Therm ADC 120
34. Therm ADC 100
41. MHV test
42. Dev bias test
43. THV EN/NEG test
44. THV ON (1300V)
45. THV ADC (1300V)
46. THV ON 600-
3500V
B273
Description
The motor starts when you press the
execution key is present, and stops
when the stop key is pressed.
Automatically stops when execute is
selected.
The fan starts when the execution
key is pressed and stops when the
stop key is pressed.
Tray 2, 3 clutch stays on for 1
second and then automatically turns
off when execute is selected. The
main motor runs 2 seconds before to
check the clutch condition.
The PTL lights when the execute key
is pressed and stops when the stop
key is pressed.
The laser motor starts when the
execute key is pressed and stops
when the stop key is pressed.
The LSU motor starts and 'Laser
Ready' appears, if the motor spins at
the correct speed. Otherwise 'Laser
Error' is shown.
'Diode On' shows when the laser
diode is on. Otherwise, "Diode off" is
shown.
These show the current state of the
sensor.
This shows the current state of the
cover sensor. Touch the sensor to
confirm that the message changes
from "Cover Open" to "Cover
Closed".
These show the current state of the
sensor.
"Current Value" appears on the
upper line of the LCD. "Target Value"
appears on the bottom line.
(Target value is limited to between
80°-191° C.)
These functions ensure that the
HVPS is functioning correctly.
5-14
Display
Main motor on/off
Tray 1, 2 solenoid on/off
Fan on/off
Tray 2, 3 clutch on/off
PTL on/off
Laser motor on/off
Laser ready on/off
Diode on/off
Sensor "off" or sensor "on"
Cover "open" or cover "close"
Sensor "off" or sensor "on"
Target temperature and
output temperature from
thermistor and ADC.
MHV on/off
Dev bias on/off
THV EN/NEG on/off
THV on/off
ADC value shows
ADC value shows
SM