4.5.11 GHOST 3

Description: Image "Ghosting" appears on the output print at
66.3 or 75.5 mm intervals.
Cause
Fusing unit is contaminated

4.5.12 GHOST 4

Description: White or pale "ghosting" appears on the output
prints at 32 mm intervals.
Cause
1.
Developer has reached end of life.
2.
Incorrect output from the HVPS.
SM
PRINTING QUALITY PROBLEMS
Solution
Disassemble the fusing unit and remove
matter from the rollers. Clean particles
between the thermistor and the hot roller.
(Use caution. Do not damage the rollers.)
Solution
1.
Replace the toner cartridge.
2.
Check the HVPS supply voltage. Clean
the HV terminals on the cartridge and
cartridge set. Replace the HVPS if the
problem persists.