Displaying Devices within the Fabric

To verify that you have fabric-wide connectivity when you install a new switch,
display the fabric-wide Fibre Channel address list from the newly installed switch.
Use these steps to display the fabric.
1. Log in to the switch as the admin user.
2. At the command line enter the following command:

Checking the Firmware Version

Use these steps to display the SAN Switch 2/8 firmware version.
1. Log in to the switch as the admin user.
2. At the command line enter the following command:
This command displays the Kernel version, and Fabric OS release number.

Setting the Switch Date and Time

All switches maintain current date and time in non-volatile memory. Date and
time are used for logging events. Switch operation does not depend on the date
and time; a switch with an incorrect date and time value still functions properly.
Use these steps to set the date and time of a switch.
1. Log in to the switch as the admin user.
2. At the command line enter the following command:
SAN Switch 2/8 Version 3.1.x Installation Guide
nsAllShow
This command displays a list of Fibre Channel addresses for all devices in the
fabric.
version
date MMDDhhmmYY
where:
— MM is the month, valid values are 01–12
— DD is the date, valid values are 01–31
— hh is the hour, valid values are 00–23
— mm is minutes, valid values are 00–59
— YY is the year, valid values are 00–99
Managing the SAN Switch 2/8