Error code
983 <device> comm
984 <device> comm
990 <device>
991 <device> Card

1xx service errors

100 ITU Error
101 ITU Error
102 ITU Error
Action
Invalid command received by the specified device.
• Engine
• Duplex option
• Tray x (where x=1,2,3,4, or 5)
• Output bin (where x=1,2,3, or 6)
Note: This message is used for single bin output devices.
• Bin x to y (where x to y=1 to 5).
Note: This message is used for multiple bin output devices.
Check the autoconnects above and below the failing option to make sure
they are seated and connected correctly. Go to service check for the
device indicated.
Invalid command parameter received by the specified device.
• Engine
• Duplex option
• Tray x (where x=1,2,3,4, or 5)
• Output bin x (where x=1,2,3, or 6)
Note: This message is used for single bin output devices.
• Bin x to y (where x to y=1 to 5).
Note: This message is used for multiple bin output devices.
Check the autoconnects above and below the failing option to make sure
they are seated and connected correctly. Go to service check for the
device indicated.
This error message indicates that an equipment check condition has
occurred in the specified device, but the device is unable to identify the
exact component failure.
Note: <device> can be one of the following:
• Duplex option
• Tray x (where x=1,2,3,4, or 5)
• Output bin x (where x=1,2,3, or 6)
Note: This message is used for single bin output devices.
Output bin x to y (where x=1 to 5)
Note: This message is used for multiple bin output devices.
Go to the 990 service check for the specified device.
This error message indicates that a device has detected an equipment
check in its system board.
Note: <device> can be one of the following;
• Duplex option
• Tray x (where x=1,2,3,4 or 5)
• Output bin x (where x=1,2,3, or 6)
Note: This message is used for single bin output devices.
• Output bin x to y (where x=1 to 5)
Note: This message is used for multiple bin output devices. Go to the
service check for the device indicated.
Go to the service check for the specified device.
ITU stall—go to
"100 ITU Error" on page
Invalid ITU memory—replace the ITU. See
page
4-37.
ITU shorted thermistor—replace the ITU. See
on page
4-37.
5060-00x
2-42.
"ITU assembly removal" on
"ITU assembly removal"
Diagnostic information
2-9