Sensor Test - Lexmark C750 Service Manual

Service manual
Hide thumbs Also See for C750:
Table of Contents

Advertisement

5060-00x

Sensor Test

This test verifies if the output bin sensors are working correctly.
The following Output options, if installed, are supported by this test.
Standard Bin
Output Expander
5-Bin Mailbox
To run the Output Bin Sensor Test:
1.
Select Sensor Test from the menu.
2.
Select the bin you want to test.
If Standard Bin is selected the following is displayed.
Standard Bin
F=OP
F
If Output Expander is selected the following is displayed:
<output bin>
P=OP F=OP NF=OP
P
F
NF
If 5-Bin Mailbox is selected the following is displayed:
<output bin>
P1=OP P2=OP L=NL
P1
P2
L
3.
Once the selection is displayed you can manually actuate the sensor you want to test. When the sensor is
closed (CL) displays, and when the sensor is open (OP) displays.
4.
To exit the test press Return or Stop.
3-26
Service Manual
=Standard Bin Output Bin Full Sensor
=Output Expander Pass Thru Sensor.
=Output Expander Full Sensor
=Output Expander Near Full Sensor.
=5-Bin Mailbox first Pass Thru Sensor.
=5-Bin Mailbox second Pass Thru Sensor.
=5-Bin Mailbox output level sensor where:
EM indicates the bin is empty.
NL indicates the bin contains media but the bin is not
near full nor full.
NF indicates the bin is near full.
FL indicates the bin is full.

Advertisement

Table of Contents
loading

This manual is also suitable for:

5060-00x

Table of Contents