5060-00x

Model Name

You can view the model name.

Configuration ID

Warning: Should not be changed without specific instructions from the next level support.
The configuration ID is used to communicate characteristics of certain areas of the printer that cannot be
determined by hardware sensors. The configuration ID is originally set when the printer is manufactured.
However, it needs to be reset when the system board or paper size sensing board are replaced.
1.
Select Configuration ID from the Printer Setup Menu.
The following screen is displayed:
Configuration ID
=1234567*
2.
Open the waste container door to locate a label above the waste container. The label contains the
configuration ID.
3.
The leftmost digit blinks, indicating it is the first digit to be changed. To change the value, press Menu until
the desired value is displayed. Press Select to move to the next digit. The digit blinks. Continue modifying
each digit using this method. To skip a digit, and keep its current value, press Select.
4.
When Select is pressed after the final digit, the configuration ID is validated. If the ID is invalid, the invalid
ID is displayed momentarily on the second line before the ID is displayed. If the ID is valid, then the ID is
stored in NVRAM and the printer automatically begins POR to activate the new setting.
Note: The printer begins POR in the normal mode, not in the diagnostic mode.
Note: If a configuration ID has not been set, and Check Configuration ID displays, then upon entry into
diagnostics, Configuration ID is the only diagnostic function displayed until a valid ID is entered.

Edge to Edge

Turn Edge to Edge printing on or off.

Cal Ref Adj

Warning: Should not be changed without specific instructions from the next level support.

EP SETUP

EP Defaults

The EP Defaults is used to restore each of the printer settings contained in the EP Setup menu to their factory
default value.
To restore the EP Setup settings to factory defaults, select Restore.
To exit the menu without restoring the settings to the factory defaults, select Do Not Restore.

Fuser Temp

Warning: Should not be changed without specific instructions from the next level support.

DC Charge Adjust

Warning: Should not be changed without specific instructions from the next level support.
3-32
Service Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

5060-00x

Table of Contents