Output Bin Tests; Feed Test; Feed To All Bins; Diverter Test - Lexmark C750 Service Manual

Service manual
Hide thumbs Also See for C750:
Table of Contents

Advertisement

2000-sheet trays
Use this test to determine if the 2000-Sheet Tray sensors are working correctly.
1.
Select Sensor Test from the menu for the tray you want to test.
The following is displayed:
<input tray> EM=OP
NE=OP LE=OP SC=OP
The selected tray is displayed on line 1 <input tray> either Tray 1, 2, 3, or 4.
EM
=trays empty sensor
NE
=trays near empty sensor
LE
=trays paper level sensor
SC
=input trays side cover sensor
2.
Manually actuate the bin sensor by moving the flag in and out of the sensor. OP (Open) appears when the
flag is out of the sensor, or CL (Closed) when the flag is in the sensor.

OUTPUT BIN TESTS

Feed Test

Feed to all Bins

Diverter Test

Sensor Test
Feed Test
Note: If the "Configure Bins" printer setting is link rather than mailbox, the printer selects its own internal bin
linking regardless of which output bin is selected for the feed test.
This test verifies that media can be fed to a specific output bin. No information is printed on the media because
the printhead is not turned on during this test.
To run the Output Bin Feed Test:
1.
Select Feed Test from the OUTPUT BIN TESTS menu.
2.
Select the output bin you want the paper to exit into. All output bins installed on the printer are shown on
the feed test menu.
For example, Standard Bin.
3.
Select either Single (one sheet of media feeds to the selected output bin) or Continuous (media continues
feeding to the selected output bin) until Return or Stop is pressed.
4.
Press Return or Stop to exit the test.
Feed to All Bins
One page is fed to every bin, including the finisher, if available. The test runs continuously until Return or Stop
is pressed.
Diverter Test
This test checks the operation of each mailbox output diverter. Also if more than one 5-Bin mailbox option is
installed, the test checks all of the diverters installed on the printer.
When the test is selected from the Diagnostics Menu Diverter Test Running is displayed.
This is a single test and ends upon completion.
5060-00x
3-25
Diagnostic aids

Advertisement

Table of Contents
loading

This manual is also suitable for:

5060-00x

Table of Contents