Appendix B
Pluggable Transceiver Modules
Table B-16
Table B-16
X2 Transceiver Product
Number
X2-10GB-LRM
X2-10GB-SR
X2-10GB-LR
X2-10GB-ER
X2-10GB-LX4
1. Both the average and the OMA specifications must be met simultaneously.
2. The launch power shall be the lesser of the class 1 safety limit or the maximum receive power. Class 1 laser requirements are
Table B-17
Table B-17
Item
Dimensions (H x W x D)
Operating temperature
Storage temperature

WDM Transceivers

The WDM transceiver modules are listed in
modules and illustration references.
OL-6265-03
lists the fiber loss budgets for the 10-GB X2 transceivers.
X2 Transceiver Optical Transmit and Receive Specifications
defined by IEC 60825: 2001.
lists the physical and environmental specifications for the X2 transceiver.
10-GB X2 Transceiver Physical and Environmental Specifications
Transmit Power (dBm)
0.5 (max)
–6.5 (min)
2
–1.2 (max)
–7.3 (min)
0.5 (max)
–8.2 (min)
4.0 (max)
–4.7 (min)
–0.5 per lane (max)
–6.75 per lane
Specification
0.53 x 1.41 x 3.58 in. (13.46 x 36 x 91 mm)
32° to 104°F (0° to 40°C)
–40° to 167°F (–40° to 75°C)
Table B-18
along with brief descriptions of the transceiver
Catalyst 6500 Series Ethernet Modules Installation Guide
WDM Transceivers
Receive Power (dBm)
0.5 (max)
1
–8.4 (min) (In average)
–6.4 (min) (in Optical Modulation
Amplitude (OMA))
–1.0 (max)
–9.9 (min)
0.5 (max)
–14.4 (min)
–1.0 (max)
–15.8 (min)
–0.5 (max)
–14.4 per lane
B-15