Cisco 6513 - Catalyst Switch Installation Manual page 111

Installation guide
Hide thumbs Also See for 6513 - Catalyst Switch:
Table of Contents

Advertisement

Chapter 2
Ethernet Switching Modules
Table 2-23
WS-X6196-RJ-21 and WS-X6196-21AF Ethernet Modules Physical and Environmental Specifications
Item
Dimensions (H x W x D)
Weight
Power and heat numbers
Environment
Operating temperature
Humidity (RH) ambient
(noncondensing)
Operating altitude
OL-6265-03
Specification
1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
WS-X6196-RJ-21—7.8 lb (3.54 kg)
WS-X6196-21AF—11.2 lb (5.08 kg)
WS-X6196-RJ-21 (base module):
Module current—2.74 A
Module power—115.08 W
AC-input power—143.85 W
AC heat dissipation—491.25 BTU/hour
DC-input power—154.68 W
DC heat dissipation—528.22 BTU/hour
WS-X6196-21AF (base module + PoE daughter card):
Module current—3.16 A
Module power—132.72 W
AC-input power—165.90 W
AC heat dissipation—566.55 BTU/hour
DC-input power—178.39 W
DC heat dissipation—609.19 BTU/hour
Certified for operation: 32° to 104°F (0° to 40°C)
Designed and tested for operation: 32° to 130°F (0° to 55°C)
10 to 90%
Certified for operation: 0 to 6500 ft (0 to 2000 m)
Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
10/100 and 10/100/1000 Ethernet Modules
Catalyst 6500 Series Ethernet Modules Installation Guide
2-37

Advertisement

Table of Contents
loading

Table of Contents