1-Gigabit Ethernet Modules
Table 2-42
WS-X6416-GBIC Features (continued)
Feature
Digital Optical Monitoring
(DOM) support
Module front panel LEDs
Table 2-43
WS-X6416-GBIC Ethernet Module Physical and Environmental Specifications
Item
Dimensions (H x W x D)
Weight
Power and heat numbers
Environment
Operating temperature
Humidity (RH) ambient
(noncondensing)
Operating altitude
Catalyst 6500 Series Ethernet Modules Installation Guide
2-68
Description
Supported on some GBIC transceivers
Refer to your software release notes for specific information on
Note
which GBIC transceivers support DOM and the software
release required for support.
STATUS
Green—All diagnostics pass; the module is operational.
Orange—The module is booting or running diagnostics; an
overtemperature condition has occurred.
LINK
Green—The port is active (the link is connected and operational).
Flashing orange—The port failed diagnostics and is disabled.
Orange—The port is disabled.
Red—The module is resetting; an overtemperature condition has
occurred.
If the module fails to download code and configuration
Note
information successfully during the initial reset, the LED stays
red; the module does not come online.
Off—The port is not active or the link is not connected.
Specification
1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
7.0 lb (3.17 kg)
Module current—2.81 A
Module power—118.02 W
AC-input power—147.53 W
AC heat dissipation—503.80 BTU/hour
DC-input power—158.63 W
DC heat dissipation—541.72 BTU/hour
Certified for operation: 32° to 104°F (0° to 40°C)
Designed and tested for operation: 32° to 130°F (0° to 55°C)
10 to 90%
Certified for operation: 0 to 6500 ft (0 to 2000 m)
Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)