Chapter 2
Ethernet Switching Modules
Table 2-44
WS-X6516-GBIC and WS-X6516A-GBIC Features (continued)
Feature
Digital Optical Monitoring
(DOM) support
Module front panel LEDs
Table 2-45
WS-X6516-GBIC and WS-X6516A-GBIC Physical and Environmental Specifications
Item
Dimensions (H x W x D)
Weight
OL-6265-03
Description
Supported on some GBIC transceivers.
Refer to your software release notes for specific information on
Note
which GBIC transceivers support DOM and the software
release required for support.
STATUS
Green—All diagnostics pass; the module is operational.
Orange—The module is booting or running diagnostics; an
overtemperature condition has occurred.
LINK
Green—The port is active (the link is connected and operational).
Flashing orange—The port failed diagnostics and is disabled.
Orange—The port is disabled.
Red—The module is resetting; an overtemperature condition has
occurred.
If the module fails to download code and configuration
Note
information successfully during the initial reset, the LED stays
red; the module does not come online.
Off—The port is not active or the link is not connected.
Specification
1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
8.6 lb (3.9 kg)
Catalyst 6500 Series Ethernet Modules Installation Guide