Configuring Open Trunking - HP 316095-B21 - StorageWorks Edge Switch 2/24 User Manual

Fw v06.xx/hafm sw v08.02.00 hp storageworks embedded web server user guide (aa-rtdrc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Note:
32. To configure all of the ports, make sure you go through each set. You must click
Activate for each view before moving to the next.
To configure Open Trunking:
1. Choose Configure from the navigation panel.
2. Choose the Performance tab and the Open Trunking tab. The Open
Figure 19: Configuring Open Trunking
3. Choose Enabled in the Open Trunking State drop down list.
4. Choose Enabled or Disabled from the Unresolved Congestion Event
5. Choose Enabled or Disabled from the Backpressure Event Notification
6. Specify a value for the Low BB Credit Threshold option, if desired.
Embedded Web Server User Guide
For the Director 2/140, ports are displayed through several pages in groups of
Trunking tab view displays
Notification drop down list. If enabled, an unresolved congestion entry is
made in the event log and, if SNMP is configured, an SNMP trap is generated.
Unresolved congestion occurs when a flow cannot be rerouted to another link
because it would exceed the other link's threshold.
drop down list. If enabled, a backpressure entry is made in the event log and,
if SNMP is configured, an SNMP trap is generated. Backpressure occurs
when the threshold of unavailable BB_Credits is exceeded for any link.
(Figure
19).