CHAPTER 4: Thermal Specifications

Table 4-2. SDLT 220/320 Steady State Temperatures: Library Bezel

Component
1
HiFN
2
Hydra 1
3
Hydra 2
4
Coldfire
5
3.3-5.0 V Reg
6
Front Sensor
7
Rear Sensor
8
Headboard
9
Qlogic
10
Media Sensor
(Heads)
* The number in the Case Maximum Continuous Operating Temperature column are absolute limits that
should not be exceeded. In other words, expect physical component damage or failure if you exceed these
operating temperature limits by not providing adequate air flow through the drive.
4.4.1 Temperature Comparison — SDLT 220 versus
SDLT 320
The SDLT 220 and 320 models have many characteristics in common, including
similar temperature profiles. In
operating temperature between the two models are shown highlighted in the
column.
10 degrees C
25 degrees C
Ambient
Ambient
Compression
Compression
2:1
2:1
On
Off
On
Temperature
Temperature
(degrees C)
(degrees C)
37.3
34.7
52.1
38.6
39.2
54.1
35.8
36.4
51.2
20.8
20.6
35.8
29.1
28.3
44.1
14.0
14.0
29.0
29.1
29.0
44.0
31.7
32.5
46.4
25.0
24.6
40.3
19.2
19.3
34.5
Table 4-3
and
Table
40 degrees C
Ambient
Compression
2:1
Off
On
Off
Temperature
(degrees C)
49.7
66.5
64.6
54.4
68.5
69.5
51.5
65.8
66.6
35.8
50.8
50.9
43.5
59.0
58.7
29.0
44.0
44.0
43.9
59.0
58.9
46.9
60.2
61.2
39.9
55.4
55.2
34.5
49.3
49.6
4-4, the differences in
Case
Maximum *
Continuous
Operating
Temperature
(degrees C)
96
113
113
83
119
52
125
125
80
n/a