CHAPTER 2: General Drive Specifications

2.9.3 Front Panel Cleaning Light

The Cleaning Required (yellow) LED on the front panel indicates to the operator
that cleaning is needed. This feature is enabled by the EEPROM parameter
EnaCleanLight. The location of the Cleaning Required LED (and other front
panel LEDs) is shown in
If EnaCleanLight is enabled, the yellow LED illuminates steadily for these
conditions:
When a HWE(Hard Write Error)/HRE(Hard Read Error) is encountered, and
more than 100 hours have passed since the last cleaning.
Once illuminated, the yellow LED stays lit until one of the following occurs:
1) drive is cleaned successfully, or 2) the drive is reset due to a firmware failure or
firmware update, or 3) power is cycled off and on.
Figure
2-7.

Figure 2-7. Front Panel LEDs