2.7.1 Temperature and Humidity

The ambient operating environment for the tape drive may not exceed the limits
shown in
Table
internal and tabletop tape drives.)

Table 2-11. Temperature and Humidity Specification

Specification
Wet Bulb Temperature
Dry Bulb Temperature
Range
Temperature Gradient
Relative Humidity
Humidity Gradient

2.7.2 Air Flow Requirements

Adequate air flow must be provided for the internal unit to dissipate the heat
resulting from drive operation (see
more details about temperatures inside the drive, and illustrations showing where
air flow and various temperatures are measured). The air flow must be sufficient to
keep the tape path temperature below 52°C.
N
: It is important to realize that the amount of air flow
OTE
provided for the tape drive determines the maximum
ambient temperature in which the drive can operate.
2-11. (The specifications shown in the table are valid for both the
Operating Limits
25°C (77°F)
10°C to 40°C (50°F to 104°F)
11°C (20°F) / hour (across range)
20% to 80% (non-condensing)
10% / hour
CHAPTER 4, "Thermal Specifications"
CHAPTER 2: General Drive Specifications
Non-Operating Limits
(Power On; No Tape
Loaded)
25°C (77°F)
10°C to 40°C (50°F to 104°F)
15°C (27°F) / hour (across range)
10% to 90% (non-condensing)
10% / hour
for