CHAPTER 4: Thermal Specifications
If a SCSI command is aborted as a result of the over-temperature condition,
the drive returns status of: Hardware Error, Warning — Specified Temperature
Exceeded (04h, 0Bh, 01h).

4.2 Air Flow Measurements

Air flow is measured in the location shown in
the air flow needs to be at least 125 LFM (linear feet per minute).
Figure 4-1. Library Bezel—Where to Measure Air Flow
Figure
4-1. At the specified location,
Measure Air
Flow Inside
the Gray Area