Compaq ProLiant 2500 Maintenance And Service Manual page 99

Proliant 2500 series
Hide thumbs Also See for ProLiant 2500:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
Logical Drive X status = RECOVERING
A physical drive in this logical drive has failed and has now been replaced. The replaced
drive is rebuilding from the mirror drive or the parity data.
Nothing needs to be done. Normal operations can occur.
Logical Drive X status = WRONG DRIVE REPLACED
A physical drive in this logical drive has failed. The incorrect drive was replaced.
Replace the drive that was incorrectly replaced. Then, replace the original drive that failed
with a new drive. Do not run the System Configuration Utility to reconfigure—you will
lose data on the drive.
Mirror data miscompare
Data was found at re-initialization in the posted write memory, however, the mirror data
compare test failed resulting in data being marked as invalid. Data loss is possible.
Replace the array accelerator board.
Mirrored memory location errors
Soft errors occurred when attempting to read the same data from both sides of the mirrored
memory. Data loss will occur.
Replace the array accelerator board.
No configuration for Accelerator Board
The array accelerator board has not been configured.
If the array accelerator board is present, run the System Configuration Utility to configure
the board.
Physical Drive (bay) X error occurred
This message displays detailed information on any drive errors that were returned to
DAAD while issuing drive commands.
Check for other error conditions.
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
3-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant 2500r

Table of Contents