POST Error Messages
1773-Primary Fixed
Disk Port
Assignment
Conflict
1776-Drive Array -
SCSI Port
Termination Error
1777-Drive Array
Error
1778-Drive Array
resuming
Automatic Data
Recovery process
1779-Drive Array
Controller detects
replacement drives
1780-Disk 0 Failure
1781-Disk 1 Failure
Continued
Error Code
Beeps
None
None
None
None
None
None
None
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
Probable Source of
Problem
Fixed disk drive error.
External and internal
SCSI drives are both
configured to Port 1.
Cooling fan failure,
internal temperature
alert or open cover.
This message appears
whenever a controller
reset or power cycle
occurs while Automatic
Data Recovery is in
progress.
Intermittent drive
failure and/or possible
loss of data.
Hard drive/format
error.
Hard drive/format error
Action
Run the System
Configuration Utility
and correct.
Re-configure drives.
Inspect for cooling fan
failure or open cover.
No action necessary.
If this message appears
and drive X has not
been replaced, this
indicates an
intermittent drive
failure. This message
also appears once
immediately following
drive replacement
whenever data must
be restored from
backup.
Run Diagnostics.
Replace failed
assembly as indicated
or contact your service
provider.
Run Diagnostics.
Replace failed
assembly as indicated
or contact your service
provider.
3-13