Replacing Non-Hot-Pluggable Hard Drives - Compaq ProLiant 2500 Maintenance And Service Manual

Proliant 2500 series
Hide thumbs Also See for ProLiant 2500:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
To Install a Drive
1. Slide the hot-pluggable hard drive all the way into the drive cage.
2. Swing the ejector levers in to seat the drive tray into the backplane connector.

Replacing Non-Hot-Pluggable Hard Drives

Figure 2-15. Removing a Non-Hot-Pluggable Hard Drive
1. Remove the large access panel.
2. Disconnect the power and signal cables from the rear of the hard drive.
3. Squeeze the two release tabs on each side of the drive and slide the drive out.
Reverse steps 1 to 3 to replace a non-hot-pluggable hard drive.
IMPORTANT: Ensure that the SCSI ID setting on the replaced non-
hot-pluggable drive matches the SCSI ID setting on the removed
drive.
MSG018.EPS
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
2-17