Error
Code
1900-xx
1901-xx
1902-xx
1903-xx
1904-xx
1905-xx
1906-xx
Tape Drive Test Error Codes
Description
Tape ID failed
Tape servo write failed
Tape format failed
Tape drive sensor test failed
Tape BOT/EOT test failed
Tape read test failed
Tape write/read/compare test failed
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
Table 3-13
Recommended Action
The following steps apply to error
codes 1900-xx through 1906-xx:
1. Replace the tape cartridge
and retest.
2. Check and/or replace the
signal cable and retest.
3. Check the switch settings on
the adapter board (if
applicable).
4. Replace the tape adapter
board (if applicable) and
retest.
5. Replace the tape drive
and retest.
6. Replace the system board
and retest.
3-31