Compaq ProLiant 2500 Maintenance And Service Manual page 69

Proliant 2500 series
Hide thumbs Also See for ProLiant 2500:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
POST Error Messages
1789-Drive Not
Responding,
Physical Drive
Check cables or
replace physical
drive X .
Select "F1" to
continue - drive
array will remain
disabled.
Select "F2" to fail
drive(s) that are
not responding -
Interim Recovery
Mode will be
enabled if
configured for fault
tolerance.
1790-Disk 0 Error
1791-Disk 1 Error
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive
array.
Continued
Error Code
Beeps
None
None
None
None
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
Probable Source of
Problem
Cable or hard drive
failure.
Hard drive error or
wrong drive type.
Hard drive error or
wrong drive type.
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory. Power was
then restored within
eight to ten days, and
the data in the Array
Accelerator was
flushed to the drive
array.
Action
1. Check the cable
connections.
2. If cables are
connected, replace
the drive.
3. If you do not want
to replace the drives
now, press F2.
Run the System
Configuration Utility
and Diagnostics and
correct.
Run the System
Configuration Utility
and Diagnostics and
correct.
No action necessary;
no data has been lost.
Perform orderly system
shutdowns to avoid
data remaining in the
Array Accelerator.
3-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant 2500r

Table of Contents