POST Error Messages
Error Code
1799-Drive Array - Drive(s)
Disabled due to Array
Accelerator Data Loss.
Select "F1" to continue
with logical drives
disabled.
Select "F2" to accept
data loss and to re-
enable logical drives.
(Run System
Configuration Utility =
"F10" key)
No keyboard present
Warning - Move bridge
card in slot x to available
slot 4, 5, 6
( x = 1, 2, or 3)
(RESUME = "F1" KEY)
Continued
Beeps
Probable Source of
Problem
None
Volume failed due
to loss of data in
posted-writes
memory.
2L,2S
Power is cycled.
Temperature too
hot. Processor fan
not installed or
spinning.
None
A configuration
error occurred
during POST.
None
None.
None
Bridge card
detected in slot 1, 2,
or 3.
None
As indicated to
continue.
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
Action
Press F1 to continue
with logical drives
disabled or F2 to
accept data loss and
re-enable logical drive.
Check fans.
Press F10 to run System
Configuration Utility.
Move bridge card to
slot
4, 5, or 6.