Diagnostic Tools
3-42
Disable command issued
Posted writes have been disabled by the issuing of the Accelerator Disable command. This
occurred because of an operating system device driver.
Restart the system. Run the System Configuration Utility to reinitialize the array
accelerator board.
Drive (bay) X needs replacing (DAAD Error 102)
The 210-megabyte hard drive installed in the computer has firmware version 2.30
or 2.31.
Replace the drive.
Drive Monitoring features are unattainable
DAAD was unable to get the monitor and performance data due to a fatal command
problem such as drive time-out, or was unable to get the data due to these features not
being supported on the controller.
Check for other errors (for example, time-outs). If no other errors occur, upgrade the
firmware to a version that supports monitor and performance, if desired.
Drive Monitoring is NOT enabled for drive bay X
The monitor and performance features have not been enabled.
Run the Compaq Diagnostics Utility 8.05 or higher to initialize the monitor and
performance features.
Drive time-out occurred on physical drive bay X
DAAD issued a command to a physical drive and the command was never acknowledged.
The drive or cable may be bad. Check the other error messages on the Diagnostics screen
to determine resolution.
Drive (bay) X firmware needs upgrading
The firmware on this physical drive is below the latest recommended version.
Call your Authorized Compaq Reseller to obtain the latest upgraded firmware.