Automatic Server Recovery
Base Memory Parity Error
Automatic Server Recovery
Extended Memory Parity Error
Automatic Server Recovery
Memory Parity Error
Automatic Server Recovery
Reset Limit Reached
Error Detected On Boot Up
NMI - Expansion Board Error
NMI - Expansion Bus Master
Time-Out
NMI - Expansion Bus Slave Time-
Out
NMI- Fail-Safe Timer Expiration
Processor Exception
NMI- Processor Parity Error
Server Manager Failure
NMI - Software Generated
Interrupt Detected Error

Revision History Table

Some errors can be resolved by reviewing changes to the Compaq ProLiant configuration.
The Server has an Automatic Revision Tracking (ART) feature that helps you review recent
changes to the Server's configuration.
Critical Error Log Error Messages
Error Message
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
Table 3-18
Description
The system detected a data error in base
memory following a reset due to the Automatic
Server Recovery (ASR) Timer expiration.
The system detected a data error in extended
memory following a reset due to the ASR Timer
expiration.
The system ROM was unable to allocate enough
memory to create a stack. Then, it was unable to
put a message on the screen or continue
booting the Server.
The maximum number of system resets due to the
ASR timer expiration has been reached, resulting
in the loading of Compaq Utilities.
The Server detected an error during the Power-
On Self-Test.
A board on the expansion bus indicated an error
condition, resulting in a Server failure.
A bus master type expansion board in the
indicated slot did not release the bus after its
maximum time, resulting in a Server failure.
A board on the expansion bus delayed a bus
cycle beyond the maximum time, resulting in a
Server failure.
Software was unable to reset the system fail-safe
timer, resulting in a Server failure.
The indicated processor exception occurred.
The processor detected a data error, resulting in
a Server failure.
An error occurred in the Server interface with the
Server Manager/R.
Software indicated a system error, resulting in a
Server failure.