POST Error Messages
1794-Drive Array -
Array Accelerator
Battery Charge
Low.
Array Accelerator
is temporarily
disabled.
Array Accelerator
will be re-enabled
when battery
reaches full
charge.
1795-Drive Array -
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily
disabled.
1796-Drive Array -
Array Accelerator
Not Responding.
Array Accelerator
is temporarily
disabled.
1797-Drive Array -
Array Accelerator
Read Error
Occurred.
Data in Array
Accelerator has
been lost.
Array Accelerator
is disabled.
Continued
Error Code
Beeps
None
None
None
None
Compaq ProLiant 2500 Family of Servers Maintenance and Service Guide
Probable Source of
Problem
This is a warning that
the battery charge is
below 75%. Posted
writes are disabled.
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory.
The data stored in the
Array Accelerator does
not correspond to this
drive array.
Array Accelerator is
defective or has been
removed.
Hard parity error while
reading data from
posted writes memory.
Action
Replace the Array
Accelerator board if
batteries do not
recharge within 36
power-on hours.
1.
Match the Array
Accelerator to the
correct drive array.
-Or-
2.
Run the System
Configuration Utility
to clear the data in
the Array
Accelerator.
1.
Check that the
Array Accelerator is
properly seated.
2.
Run the System
Configuration Utility
to re-configure the
array controller
without the Array
Accelerator.
Enable Array
Accelerator.
3-19