168
Monitoring Interfaces
For definitions of the MIB statistics for a T3 connections, see RFC
2496 Definitions of Managed Objects for the DS3/E3 Interface Types (January
1999).
For definitions of the MIB statistics for a T1 connections, see RFC
2495 Definitions of Managed Objects for the DS1, E1, DS2 and E2 Interface
Types (January 1999).
Field descriptions for a T3 interface
Far End MDL Carrier bit Status of MDL configuration on remote device
connected to T3 interface
set MDL is configured for carrier mode
not set MDL is not configured for carrier mode
Far End Equipment Identification Code eic string sent by remote device
for MDL
Far End Line Identification Code lic string sent by remote device for MDL
Far End Frame Identification Code fic string sent by remote device for MDL
Far End Unit Identification Code unit string sent by remote device for MDL
Far End Facility Identification Code pfi string sent by remote device for
MDL
Far End Generator Number generator string sent by remote device for MDL
Far End Port Number port string sent by remote device for MDL
Number of valid intervals Number of 15-minute intervals since the line
module was last powered on or reset
Time elapse in current interval Number of seconds that have passed in the
15-minute (900-second) interval
C-bit errored seconds Number of C-bit errored seconds encountered by a
T3 in the current interval
C-bit severely errored seconds Number of C-bit severely errored seconds
encountered by a T3 in the current interval
C-bit coding violations Number of C-bit coding violations encountered by
a T3 in the current interval
Unavailable seconds Number of unavailable seconds encountered by a T3
in the current interval
Invalid seconds Number of seconds when statistics were not collected
Field descriptions for a T1 channel
DS1 Identifier of T1 channel
Number of valid intervals Number of 15-minute intervals since the line
module was last powered on or reset