Juniper JUNOSE 10.0.X PHYSICAL LAYER Configuration Manual page 93

For e series routing platforms - physical layer configuration
Table of Contents

Advertisement

MDL Transmit Idle-Signal Indicates if the transmission is active or not active
(T3 only)
Equipment Identification Code eic string for MDL (T3 only)
Line Identification Code lic string for MDL (T3 only)
Frame Identification Code fic string for MDL (T3 only)
Facility Identification Code fic string for MDL (T3 only)
Equipment Port port string for MDL (T3 only)
Unit Identification Code unit string for MDL (T3 only)
Facility Identification Code pfi string for MDL (T3 only)
Port Code port string for MDL (T3 only)
Generator Number generator string for MDL (T3 only)
BERT test Number of current test and total number of tests (T3 only)
Test interval Length of the BERT test
status Sync (controller is synchronized with remote device) or NoSync
(controller is not synchronized with remote device)
Sync count Number of times the pattern detector synchronized with
the incoming data pattern
Received bit count Number of bits received
Error bit count Number of bits with errors
Number of valid intervals Number of 15-minute intervals since the T3 or
E3 module was last powered on or reset
Time elapse in current interval Number of seconds that have passed in the
15-minute (900 second) interval
Errored seconds Number of errored seconds encountered by an E3 (not
applicable for T3) in the current interval (this field is not present for T3
controllers)
P-bit errored seconds Number of errored seconds encountered by a T3
(not applicable for E3) in the current interval (this field is not present for E3
controllers)
Severely errored seconds Number of severely errored seconds encountered
by an E3 (not applicable for T3) in the current interval (this field is not present
for T3 controllers)
P-bit severely errored seconds Number of severely errored seconds
encountered by a T3 (not applicable for E3) in the current interval (this field
is not present for E3 controllers)
Chapter 2: Configuring T3 and E3 Interfaces
Monitoring Interfaces
67