Field Diagnostics for the Cisco 12000 Series Router
Using the diag Command
FD 3> GSR Field Diagnostics V6.01
FD 3> Compiled by award on Tue Apr 9 07:22:53 PDT 2002
FD 3> view: award-conn_isp.f_diag_new
FD 3> *****************************************************
Diagnostics have been downloaded to slot 7
Executing all diagnostic tests in slot 7
(total/indiv. timeout set to 2000/600 sec.)
FD 3> BFRP w/ECC testing...
FD 3> Secondary Discovery found ID 2
FD 3> BFR_CARD_TYPE_BFRP_CARD w/ ECC testing...
FD 3> Available test types 2
FD 3>
1
FD 3> Completed f_diags_board_discovery() (0x1)
FD 3> Verbosity now (0x00000011) TESTSDISP FATL
FD 3> Test list selection received: Test ID 1, Device 0
FD 3> running in slot 7 (24 tests from test list ID 1)
FDIAG_STAT_IN_PROGRESS(3): test #1 BFRP Dram Datapins Test
FDIAG_STAT_IN_PROGRESS(3): test #2 Dram Marching Pattern Test
FDIAG_STAT_IN_PROGRESS(3): test #3 DataPins_Sram
FDIAG_STAT_IN_PROGRESS(3): test #4 March_Sram
FDIAG_STAT_IN_PROGRESS(3): test #5 High Memory DRAM Marching Pattern
FDIAG_STAT_IN_PROGRESS(3): test #6 diags_csar_regtest
FDIAG_STAT_IN_PROGRESS(3): test #7 diags_test_p4_csar_int
FDIAG_STAT_IN_PROGRESS(3): test #8 NVRAM Memory Test
FD 3> 32 bit data compare error. Wrote 0xcccccccc, read back
0xcc41cccc at location 0xbe03fff0
FDIAG_STAT_DONE_FAIL(3) test_num 8, error_code 1
COMPLETED Field Diags: pid 128, status 5, test_num 8, error_code 1
Field Diagnostic: ****TEST FAILURE**** slot 7: first test failed: 8,
NVRAM Memory Test, error 1
Field Diag results from eeprom before updating slot 7, run# 0x5000042
were 0x0
previous field diag eeprom values: run 66 fail mode 5 (DOWNLOAD
FAILURE)
last test failed was 0, error code 0
Field Diag eeprom values: run 67 fail mode 1 (TEST FAILURE) slot 7
last test failed was 8, error code 1
Shutting down diags in slot 7
slot 7 done, will not reload automatically
The following example shows the previous test results of a line card. Diagnostics
had been run 64 times on this line card. Because the board PASSED the last field
diagnostics session, the fail mode was 0 as was the last test that failed.
Router # diag 7 prev
Field Diag eeprom values: run 64 fail mode 0 (PASS) slot 7
last test failed was 0, error code 0
Cisco 12006 and Cisco 12406 Router Installation and Configuration Guide
5-17
OL-11497-03