NOVA 4 EXERCISER
SAMPLE PROGRAM RUN SUMMARY
(No Errors Found; DTOS Auto Mode)
DTOS Mnemonic:
DTOS Directory:
DTOS Command:
Special Machine Requirements:
Estimated Program Run Times:
None
SELECT OR CSELECT
Listing No. 096-001 136
Operator Input:
*SELECT N4EXER
Program Output:
ACTIVE DIRECTORY=HOST
PROCESSOR UNDER TEST=HOST
N4EXER REV. 01
N4EXER 01 RUNNING
MMU PRESENT
TOTAL # OF 1K'S=64
PASS 1
PASS 2
PASS 3
Operator Input:
*CSELECT N4EXER
Program Output:
INPUT DATA CHANNEL EXERCISER TO BE RUN
(O = STANDARD DISK, 1 = ZEBRA DISK,
2 = I/O TESTER)
<ENTER APPROPRIATE NUMBER -
O, 1, 2, - FOLLOWED BY CARRIAGE RETURN>
N4EXER REV.
Program Output:
IS THIS A 4231 OR 6070 TYPE DISK?
(O = NO, 1 = YES)
<<ENTER APPROPRIATE NUMBER - O
Program Output:
ENTER DISK DEVICE CODE
<ENTER APPROPRIATE NUMBER -
Comments
Note 2
Notes
1.
MMU PRESENT
is
printed
when
program
is
run
on
NOVA
4/X
2.
TOTAL # 1K'S varies with system.
Note 4
3. ZEBRA DISK means DGC model 6060,6061 or 6067 disc drive.
4.
Answer "'yes'' if the disc is either a 4231 or a 6070.
5.
The remaining program output is the same as that generated when
the
program
is run
using the SELECT command,
except that
the
program outputs an ''S" at the beginning of the first pass and five
"P''s and an ''S"' during the passes as shown below. Approximately
1 minute elapses between ''P''s.
S
PASS 1
PPPPPS
PASS 2
PPPPPS
PASS 3
PPPPPS
*