GigE Server icon, then select Scan Network to restart the discovery process, which will also include conflicting
devices. After the scan, if the device is visible with the Device IP Error notification you may recover it using the
Teledyne DALSA Network Configuration tool (details in section Network Configuration Tool).
To recover a GigE camera
1. Start the Network Configuration tool from the Start menu, under Teledyne DALSA.
2. On the System Configuration tab, Select Enable Automatic Conflicted Device Detection (Broadcast).
3. Click Scan Network (at the bottom). The conflicted devices appear in red in the left pane. (If no camera is
found, you can use the Recover Camera tool. See the Getting Started manual referred to below.)
4. Select the device to recover.
5. Click Automatic Recovery (Force IP).
The Force IP address will remain valid until the device is powered off.
See the Sapera LT Getting Started Manual for GigE Vision Cameras & 3D Sensors for details on using the
Network Configuration Tool.