1. Specifications
*1) Only models with a maximum torque of 45 N・m or less can be used with single-phase 100 VAC
power.
Models with a maximum torque of 75 N ・m or more will calculate the torque limit area differently
when used with single-phase 200 VAC. Please contact us to determine if you can use it.
*2) Supply the main power and control power from the same power source. Do not supply the power
supply with a different voltage or phase.
Otherwise, it causes malfunction or damage. Use the control power supply of the single-phase 100 to
115 VAC.
If the single-phase 200 to 230 VAC is connected to the drivers by mistake, the internal circuits of the
drivers will be damaged.
[SMF-2008]
― 1-3 ―