Code
Item/Function
No.
0010h
Current alarm loading
0020h
Operation mode loading
Parameter
loading
0023h
data)
0025h
Parameter loading
Load current alarm (0010h)
The current alarm number is loaded.
It is set as loaded data. Each byte indicates the type, and up to four alarms are specified.
Alarm indication is consistent to the 7-segment LED indication. The first digit indicates details of
the alarm and the second digit indicates the alarm number. Alarms not expressed in 0 to F
Alarm H → "d"
Alarm L → "b"
Alarm P, U and others → "8"
Alarms are set in the order from "F" to "0."
In case of "no alarm," "00" is set.
Operation mode loading (0020h)
The current operation mode is loaded.
The number of the operation mode is set in the loaded data.
Parameter loading (0023h, 0025h)
The set value of the parameter designated with the parameter number (RWwn+5) is loaded
using an integer value.
A parameter with a decimal value is loaded using a value multiplied by 100 or 10,000.
For details, refer to the "Parameter list" on page 3-6.
Table 3.6. Load command code (RWwn+2) list
RWrn+3
Lower 8 bits: Alarm loading 1
Upper 8 bits: Alarm loading 2
Current operation mode No.
(RAM
Lower 16 bits of parameter
set value
Lower 16 bits of parameter
set value
Table 3.7. Loadable operation mode list
Operation Mode
Automatic operation mode
Single block mode
MDI (manual data input) mode
Jog mode
Servo OFF mode
Pulse string input mode
Network operation mode
― 3- 4 ―
3. CC-Link Communication Function
Loaded data
RWrn+4
Lower 8 bits: Alarm loading 3
Upper 8 bits: Alarm loading 4
0 (fixed)
Upper 16 bits of parameter
set value
Upper 16 bits of parameter
set value
Loaded data
Set value
1
2
3
4
5
6
7
Loaded data
designation
RWwn+5
-
-
Parameter
number
Parameter
number
[SMF-2008]