Main Operation - Panasonic AG-HPX300 Operating Instructions Manual

P2hd
Hide thumbs Also See for AG-HPX300:
Table of Contents

Advertisement

MAIN OPERATION

BATTERY/P2CARD
Items/
Adjustable
Data Saved
Range
BATTERY
PROPAC14
Select the battery to use. Remaining
capacity detection is also performed
SELECT
TRIMPAC14
according to the selected battery.
HYTRON50
The variable range is changed by the
HYTRON140
item settings selected on the [ BATTERY
DIONIC90
SETTING1 ] (page 182) and [BATTERY
DIONIC160
SETTING2] (page 183) menus.
NP-L7
The initial value for TYPE A is set to
ENDURA7
DIONIC90 while the same for TYPE B is
ENDURA10
set to HYTRON140.
ENDURA-D
When BP-GL65 or BP-GL95, a battery
PAG L95
made of Sony, is used, set this to "BP-
BP-L65/95
L65/95".
NICD14
TYPE A
TYPE B
– C U F –
Set the remaining capacity detection
EXT DC IN
AC_ADPT
type when a battery is connected to the
SELECT
PROPAC14
DC IN connector. Remaining capacity
TRIMPAC14
detection is also performed according to
HYTRON50
the selected battery type.
HYTRON140
The variable range is changed by the
DIONIC90
item settings selected on the [ BATTERY
DIONIC160
SETTING1 ] (page 182) and [BATTERY
NP-L7
SETTING2] (page 183) menus.
ENDURA7
Analog voltage is displayed on the
ENDURA10
viewfinder screen.
ENDURA-D
When BP-GL65 or BP-GL95, a battery
PAG L95
made of Sony, is used, set this to "BP-
BP-L65/95
L65/95".
NICD14
TYPE A
TYPE B
– C U F –
BATT NEAR
ON
Select whether or not to set the alarm to
OFF
beep for BATT NEAR END ALARM.
END ALARM
– C U F –
ON
If set to ON, the warning tone and
BATT NEAR
indication can be canceled by pressing
END CANCEL
OFF
the MODE CHECK button when BATT
NEAR END ALARM is triggered.
– C U F –
BATT END
ON
Select whether or not to set the alarm to
ALARM
OFF
beep for BATT END ALARM.
– C U F –
70%
Set the display of the remaining battery
BATT REMAIN
100%
level indicator bar in the display window
FULL
when a battery with this function is used.
70%: Indicate FULL at 70% capacity.
100%: Indicate FULL at 100% capacity.
– C U F –
Remarks
Data Saved
CARD NEAR
END ALARM
CARD NEAR
END TIME
CARD END
ALARM
CARD
REMAIN/
The ____ in the Adjustable Range column indicates the
preset mode.
Items/
Adjustable
Range
ON
Select whether or not to set the alarm to
OFF
beep for P2 CARD NEAR END ALARM.
– C U F –
2min
Set the remaining time to indicate the P2
3min
CARD NEAR END TIME alarm.
– C U F –
ON
Select whether or not to set the alarm to
OFF
beep for P2 CARD END ALARM.
– C U F –
3min/
Set the length of time for one segment
( ) of the P2 card's remaining capacity
5min/
indicator bars.
3min/ : One segment represents 3
5min/ : One segment represents 5
– C U F –
Menu : Menu Description Tables
Remarks
minutes.
minutes.
181

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj-hpx3000Aj-hpx3000g