MAIN OPERATION

BATTERY/P2CARD
Items/
Adjustable
Data Saved
Range
Select the battery to use. Remaining
BATTERY
PROPAC14
capacity detection is also performed
SELECT
TRIMPAC14
according to the selected battery.
HYTRON50
The variable range is changed by the
HYTRON140
item settings selected on the [ BATTERY
DIONIC90
SETTING1 ] (page 164) and [ BATTERY
DIONIC160
SETTING2 ] (page 165) menus.
NP-L7
The initial value for TYPE A is set to
ENDURA7
DIONIC90 while the same for TYPE B is
ENDURA10
set to HYTRON140.
ENDURA-D
When BP-GL65 or BP-GL95, a battery
PAG L95
made of Sony, is used, set this to "BP-
BP-L65/95
L65/95".
NICD14
TYPE A
TYPE B
– C U F –
Set the remaining capacity detection
EXT DC IN
AC_ADPT
type when a battery is connected to the
SELECT
PROPAC14
DC IN connector. Remaining capacity
TRIMPAC14
detection is also performed according to
HYTRON50
the selected battery type.
HYTRON140
The variable range is changed by the
DIONIC90
item settings selected on the [ BATTERY
DIONIC160
SETTING1 ] (page 164) and [ BATTERY
NP-L7
SETTING2 ] (page 165) menus.
ENDURA7
Analog voltage is displayed on the
ENDURA10
viewfinder screen.
ENDURA-D
When BP-GL65 or BP-GL95, a battery
PAG L95
made of Sony, is used, set this to "BP-
BP-L65/95
L65/95".
NICD14
TYPE A
TYPE B
– C U F –
BATT NEAR
ON
Select whether or not to set the alarm to
beep for BATT NEAR END ALARM.
END ALARM
OFF
– C U F –
BATT NEAR
ON
If set to ON, the warning tone and
OFF
indication can be canceled by pressing
END CANCEL
the MODE CHECK button when BATT
NEAR END ALARM is triggered.
– C U F –
BATT END
ON
Select whether or not to set the alarm to
beep for BATT END ALARM.
ALARM
OFF
– C U F –
BATT REMAIN
70%
Set the display content of the remaining
FULL
100%
battery capacity indicator bars in the
display window when using a digital
battery.
70%: Indicate FULL at 70% capacity.
100%: Indicate FULL at 100% capacity.
– C U F –
Remarks
Data Saved
CARD NEAR
END ALARM
– C U F –
CARD NEAR
END TIME
– C U F –
CARD END
ALARM
– C U F –
CARD
REMAIN/
– C U F –
The ____ in the Adjustable Range column indicates the
preset mode.
Items/
Adjustable
Range
Select whether or not to set the alarm to
ON
beep for P2 CARD NEAR END ALARM.
OFF
2min
Set the remaining time to indicate the P2
3min
CARD NEAR END TIME alarm.
ON
Select whether or not to set the alarm to
OFF
beep for P2 CARD END ALARM.
3min/
Set the length of time for one segment
( ) of the P2 card's remaining capacity
5min/
indicator bars.
3min/ : One segment represents 3
minutes.
5min/ : One segment represents 5
minutes.
Menu : Menu Description Tables