8-6 MAIN OPERATION

8-6-1 BATTERY/P2CARD

Items/
Adjustable
Data Saved
Range
BATTERY
PRO14
SELECT
TRIM14
HYTRN50
HYTRN100
HYTRN120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
– C U F –
EXT DC IN
AC_ADPT
SELECT
PRO14
TRIM14
HYTRN50
HYTRN100
HYTRN120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
– C U F –
BATT NEAR
ON
END ALARM
OFF
– C U F –
BATT NEAR
ON
END CANCEL
OFF
– C U F –
BATT END
ON
ALARM
OFF
– C U F –
BATT REMAIN
100%
FULL
70%
– C U F –
Downloaded From CamcorderManual.com Panasonic Manuals
116
Remarks
Select the battery to use. Remaining
capacity detection is also performed
according to the selected battery.
The selectable battery types change
depending on the settings under [8-6-2
BATTERY SETTING1] and [8-6-3 BATTERY
SETTING2].
Set the remaining capacity detection type
when a battery is connected to the DC IN
connector. Remaining capacity detection is
also performed according to the selected
battery type.
The selectable battery types change
depending on the settings under [8-6-2
BATTERY SETTING1] and [8-6-3 BATTERY
SETTING2].
<Note>
The % display is disabled even when a
digital battery is connected to the DC IN
connector.
Select whether or not to set the alarm to
beep for BATT NEAR END ALARM.
If set to ON, the warning tone and indication
can be canceled by pressing the MODE
CHECK button when BATT NEAR END
ALARM is triggered.
Select whether or not to set the alarm to
beep for BATT END ALARM.
Set the display content of the remaining
battery capacity indicator bars in the display
window when using a digital battery.
100%: Indicate FULL at 100% capacity.
70%: Indicate FULL at 70% capacity.
Items/
Adjustable
Data Saved
Range
CARD NEAR
ON
Select whether or not to set the alarm to
END ALARM
OFF
beep for P2 CARD NEAR END ALARM.
– C U F –
CARD NEAR
3min
Set the remaining time to indicate the P2
END TIME
2min
CARD NEAR END TIME alarm.
– C U F –
CARD END
ON
Select whether or not to set the alarm to
ALARM
OFF
beep for P2 CARD END ALARM.
– C U F –
CARD REMAIN/ 5min/
Set the length of time for one segment ( ) of
the P2 card's remaining capacity indicator
3min/
bars.
5min/ :One segment represents 5 minutes.
3min/ :One segment represents 3 minutes.
– C U F –