Adjustable
Data Saved
Range
TCG SET
ON
HOLD
OFF
– C U F –
FIRST REC
PRESET
TC
REGEN
– C U F –
P.OFF LCD
ON
OFF
DISPLAY
– C U F –
TC OUT
TCG
TCG/TCR
– C U F –
TC DISP SEL 30F
24F
– C U F –
TC VIDEO
0
SYNCRO
1
2
3
– C U F –
186
Menu : Menu Description Tables
Remarks
ON/OFF switching for the feature that
always starts recording (when the power
is turned ON again) the TCG value that
was set before the power is turned OFF.
For the first recording after the power is
turned on, a P2 card is inserted and
then switching from this P2 card to
another recording-target P2 card is
performed, select whether or not to
regenerate the time code as the value
on the new P2 card.
PRESET:
Use the camera-recorder's internal
time code.
REGEN:
For clips recorded on the recording-
target P2 card, regenerate the time
code as the time code of the clip that
has the most recent date and time.
Notes
Set the date and time accurately. For
guidance on setting, see [ Setting the
Internal Clock's Date and Time ] (page
59).
During operation in either 24P or
24PA mode, regeneration of the value
of the card recorded in drop-frame is
not permitted.
Select whether or not to display the time
code setting and counter indication on
the LCD monitor when the power is
turned OFF.
ON: Display setting and indication while
the power is turned OFF.
OFF: Power-down LCD monitor while
camera power is turned OFF.
Setting and indication disabled.
Select the time code to be output to the
time code output connector.
TCG:Always output time code generator
value.
TCG/TCR:
Display time code generator value
in recording mode, and time code
reader value in playback mode.
Select the display format for the time
code frame digits. (For 1080-59.94i or
480-59.94i only For details, refer to
[Recording time code and user bits]
(page 56).
30F: Display time code frame digits in 30
frames.
24F: Convert time code frame digits into
24 frames for display.
For setting to correct the time code
according to the delay of video signals.
0: Do not correct.
1: To delay the time code to be input
according to the timing of the video
images.
2: To forward the time code to be output
according to the timing of the video
images.
3: To delay the time code to be input and
forward the time code to be output,
respectively, according to the timing of
the video images.
For details, refer to [Externally Locking
the Time Code] (page 61).
Items/
Adjustable
Data Saved
Range
For selecting whether the time code is
REC REVIEW
ON
REGEN
OFF
regenerated to the value on the P2 card
or not, when subsequent recording
starts after setting the RET SW item on
the SW MODE screen to R.REVIEW
and pressing the RET button on the lens
or the USER button on the unit on which
the RET SW function is assigned.
ON: The time code is regenerated to
OFF: The time code is not regenerated.
– C U F –
UMID SET/INFO
Items/
Adjustable
Data Saved
Range
NO-INFO
Input the user's country. NO-INFO is
COUNTRY
displayed until the input completes.
– C U F –
ORGANIZATION NO-INFO
Input the user's organisation or
company name. NO-INFO is displayed
until the input completes.
– C U F –
USER
NO-INFO
Input the user name. NO-INFO is
displayed until the input completes.
– C U F –
DEVICE
Indicate the product ID number.
NODE
– – – – –
Note
Please refer to [ Setting UMID Information ] (page 66) for the
UMID information setting.
The ____ in the Adjustable Range column indicates the
preset mode.
Remarks
the value on the tape.
Remarks