Returning to Factory Default Setup
EasyCoder PX4i Bar Code Label Printer User's Guide (Fingerprint Version)
Print Speed
The print speed is variable between 100 and 300 mm/sec.
Generally, the lower the speed, the better the printout quality.
This is especially true when printing bar codes with the bars
running across the media path ("ladder style"), when printing on
demanding face materials, and when printing at low ambient
temperatures. The default setting is 200 mm/sec (approximately
8 in/sec).
Refer to
"Intermec Supplies" on page 161
maximum print speed for various combinations of Intermec
media and transfer ribbon.
LSS Test
The function on the label stop sensor (LSS) can be tested
automatically or manually as described in
page
129.
LTS (Label Taken Sensor)
The sensitivity of the LTS can be tested and adjusted as described
in
"Adjustments" on page
There are two ways to return to the factory default setup of the
printer:
• Insert a special CompactFlash memory card and restart the
printer.
• Use the printer's built-in keyboard.
To return to factory default setup using the keyboard
1 Lift the printhead.
2 Switch on the power to the printer and press F5/i and wait
until the printer beeps.
Quickly press the following keys:
/F4,
/F2,
/F2,
3 The following message will be displayed:
Factory Default?
Enter=Yes ESC=No
Chapter 6 — Setting Up the Printer
for recommended
"Adjustments" on
129.
/F1
75