Download Print this page

Electrical Connections - Insinger ADMIRAL 44-4 Technical Manual

Admiral series rack conveyor dishmachines
Hide thumbs Also See for ADMIRAL 44-4:

Advertisement

INSTALLATION INSTRUCTIONS
Placement
Carefully uncrate machine. Take caution not to
damage components which may be mounted on
the top or sides of the machine. Set unit in place
and adjust the feet to level the machine.
Fasten the tables to the load and unload side of the
machine. Most installations require fastening the
turn-down lip of the dish table to the side of the
machine with flathead counter-sunk screws. The
table design should provide horizontal clearance of
30" for servicing underneath the table.

Electrical Connections

Connect electrical lines sized for the correct volt-
age, current and phase of the machine. These
should agree with the machine requirements
indicated on the nameplate and labels on the
control panel.
Model
Admiral 44-4
Steam or Electric
Admiral 44-4
Steam or Electric
Power Loader
Admiral 44-4
Steam or Electric
Power Unloader
Admiral 44-4
Steam or Electric
Power Loader
Power Unloader
Admiral 44-4
Gas Heat
Admiral 44-4
Gas Heat
Power Loader
Power Unloader
Admiral 44-4
Admiral 66-4
Electric Heat
Single-Point Electric
Admiral 44-4
Electric Heat
Single-Point Electric
Power Unloader
Admiral Series DOC ADM-ES 1.0 04
FUSE SIZING CHART
208VAC/3È
230VAC/3È
15A
15A
15A
20A
15A
15A
60A
60A
PART 2 INSTALLATION INSTRUCTIONS
On machines not provided with a single-point con-
nection (optional) there is an electrical connection
required for the: 1. Pumps and control circuit, 2.
Wash tank heater(s) and, 3. Rinse tank heaters
(if provided).
If an electric booster is provided, connect power
directly to the booster.
Fusing must be in accordance with the Fuse Sizing
Chart below.
Connections must be made to a circuit breaker
or fused disconnect as provided by the
end-user and required by local codes.
A laminated wiring diagram is inside the control panel.
380VAC/3È
10A
10A
15A
10A
15A
10A
15A
10A
15A
10A
15A
10A
50A
30A
50A
30A
12
CAUTION:
460VAC/3È
6A
6A
10A
10A
6A
10A
25A
25A
www.insingermachine.com 800-344-4802
220VAC/IÈ
20A
25A
25A
25A
20A
25A
n/a
n/a

Advertisement

loading

This manual is also suitable for:

Admiral 66-4