Electrical - Insinger 45SA Technical Manual

Undercounter dishwasher
Table of Contents

Advertisement

Insinger Model 45SAS
8.2.2
Electrical.
~
WARNING
Dangerous voltages are present on connections
to the electrical control enclosure and
electric booster heater.
Observe normal
safety precautions for high voltage
electrical equipment when connecting to the
local distribution system.
All work should
be done by a qualified electrician.
NOTE
Mounting hardware for the electrical control
enclosure and the electrical power cables
from the electrical control enclosure and
electric booster heater to the ship's local
distribution panel are to be furnished by the
installing activity.
8.2.2.1
Install the electrical control enclosure on a
bulkhead adjacent to the dishwasher.
Controls should be
easily accessible by the operator.
8.2.2.2
Install the 440 volt power wires between a circuit
breaker in the ship
1
s local distribution panel and the
dishwasher electrical control enclosure.
NOTE
Power requirements for the dishwasher and
booster heaters are listed in Table 1-1.
8.2.2.3
For electric booster heaters only, .install separate
440 volt power wires between a circuit breaker in the ship's
local distribution panel and the 440 volt connections inside
the booster main cover panel.
8.2.2.4
Install the power and control wires between the
electrical control enclosure and the junction box on the
dishwasher.
Numbered terminals are provided in each
enclosure for all wires.
See Figure 8-5.
8-3